Flow type air tightness detector


                                        SLF flow tightness tester, airflow tester with flow sensor as the core, mainly used in air permeability testing, waterproof and breathable testing, etc.

                                        Contact

                                        SLF flow air tightness tester is a gas tightness tester with flow detection method. The air tightness tester with flow sensor as the core is mainly used in the fields of air permeability detection, air flow detection, waterproof and ventilation test.

                                        The SLF flow tightness tester uses air as the detection medium. Leak detection with gas is based on the fact that all media (gas) have small and low molecular weight and good permeability. Under certain pressure (positive or negative pressure), the leakage performance of the product is checked. Air tightness."

                                        The principle of the flow tightness tester is: use the sum of the "leakage" of the product to be tested as the participation value to "leakage rate", or the "pressure drop" under the specified conditions, or the "flow rate of the gas within a certain period of time" "To determine the sealing of the product. The core component is a secondary sensor developed by a flow sensor and calculated by an algorithm to obtain a leak rate.

                                        SLF air tightness detector, the test pressure can be automatically determined, the upper and lower limits of the flow rate are automatically determined, the air tightness detection speed is fast, the efficiency is high, and the power self-test is performed.

                                        Hailim SLF flow air tightness detector comes with air filter adjustment and stability system, unique internal stability loop, enough to ensure the stability of air tightness detection and waterproof detection.

                                        Multi-channel data storage function (convenient to record multiple product detection data separately), the core components are all imported, guarantee quality, and airtight leak detection accuracy, flow leak detector stability, multi-functional input and output interface.



                                        Flow tightness testermodelSLF

                                        PrecisionLess than 士0.1%FS

                                        Repeatability

                                        Less than 士0.02%FS


                                        Display accuracy

                                        1PA


                                        Humidity error

                                        士0.05%FS
                                        Test range (optional)

                                        1

                                        0sccm~50sccm



                                        0sccm~100sccm


                                        0sccm~500sccm


                                        0sccm~5000sccm


                                        0sccm~100000sccm


                                        Number of programs

                                        32 sets of test programs, each set of programs is set independently


                                        data storage

                                        Can store the latest 100,000 sets of test data, plug in the U disk to export test data

                                        Interface

                                        RS232

                                        one

                                        USB

                                        two

                                         I/O interface

                                        8 output/8 input


                                        power supply

                                        External 240V power supply

                                        data analysis

                                        Statistical Analysis

                                        The  instrument performs the following statistics on the test product data:  the total number of air tightness tests, the number of passes, and the  number of unqualified

                                        Test process control

                                        Stage time display

                                        Real-time display of status and time for each test phase

                                        Instrument settings

                                        parameter settingsTest  pressure upper and lower limit setting; test each stage time setting;  flow upper and lower limit setting; flow compensation setting

                                        Equipment material

                                        Weight

                                        About 9.5 kg

                                        Shell material

                                        Aluminum alloy

                                        Software

                                        Optional

                                        The host computer software can perform test data transmission, data analysis and other functions with the instrument.

                                        Accessories

                                        Barcode scanning

                                        Bar code, QR code (optional)

                                         Size

                                        Unit: mm

                                        335*305*265